Dataprobe iBoot-G2+

Dataprobe iBoot-G2+ Web Power Switch User Manual

Model: iBoot-G2+

Remote Power Control and Management Solution

Introduksjon

The Dataprobe iBoot-G2+ is a web-enabled power switch designed for remote power control and management of connected devices. It features a single NEMA 5-15 circuit outlet, allowing users to remotely reboot, power on, or power off equipment from any location via a web browser or the iBoot Cloud Service. This device is ideal for managing remote servers, network equipment, or any device that benefits from automated power cycling to ensure continuous operation and minimize downtime. The iBoot-G2+ also includes two expansion I/O ports for custom integration with external sensors or alarms, providing enhanced flexibility for various applications.

Oppsett og installasjon

Pakkeinnhold

  • iBoot-G2+ Web Power Switch Unit
  • Strømledning
  • Ethernet-kabel
  • Terminal Blocks for Expansion Ports (2)
iBoot-G2+ unit with included power and ethernet cables

Figure 1: iBoot-G2+ unit with standard accessories.

Fysisk tilkobling

  1. Koble til strøm: Plug the provided power cord into the A/C Input port on the iBoot-G2+ and then into a standard wall outlet.
  2. Koble til nettverk: Connect an Ethernet cable from your network router or switch to the Ethernet port on the iBoot-G2+. Ensure your network has DHCP enabled for automatic IP address assignment.
  3. Koble til enhet: Plug the device you wish to control into the A/C Output port of the iBoot-G2+.
iBoot-G2+ with A/C Input, A/C Output, Ethernet, and USB ports visible

Figure 2: Rear and Front View of iBoot-G2+ showing A/C Input, A/C Output, Ethernet, and Expansion Ports.

Close-up of iBoot-G2+ A/C Output and Expansion Ports

Figur 3: Detaljert view of the A/C Output and Expansion I/O Ports (EXP1, EXP2) on the iBoot-G2+.

Innledende konfigurasjon (Web Grensesnitt)

Once connected, the iBoot-G2+ will obtain an IP address from your network's DHCP server. You can discover its IP address using the iBoot Discovery Tool (available on the Dataprobe website) or by checking your router's connected devices list.

  1. Åpne a web browser and enter the iBoot-G2+'s IP address in the address bar.
  2. Log in using the default credentials (refer to the included quick start guide for default username and password).
  3. It is highly recommended to change the default password immediately for security purposes.
  4. Configure network settings (e.g., static IP, DNS) if required for your network environment.

Utvidelse I/O-porter

The iBoot-G2+ features two expansion I/O ports (EXP1 and EXP2) for integrating external devices such as sensors or alarms. These ports allow for customized power management solutions based on external triggers. Refer to the advanced user guide on the Dataprobe website for detailed instructions on configuring and utilizing these ports.

Operating the iBoot-G2+

Fjernkontroll

The primary function of the iBoot-G2+ is to provide remote control over the power to a connected device. This can be done via the web interface or the iBoot Cloud Service.

  • Strøm på: Applies power to the connected device.
  • Slå av: Removes power from the connected device.
  • Power Cycle (Reboot): Briefly removes power and then reapplies it, effectively rebooting the connected device. This is a common operation for unresponsive network equipment.

AutoPing Reboot Feature

The AutoPing feature allows the iBoot-G2+ to automatically monitor the responsiveness of a network device (e.g., a router or server) by continuously sending ping requests to a specified IP address. If the device fails to respond after a configurable number of attempts or duration, the iBoot-G2+ will automatically power cycle the connected equipment.

  • Configure target IP addresses for ping monitoring.
  • Set the ping interval and the number of failed pings before a power cycle is initiated.
  • This feature ensures minimal downtime for critical network components.

iBoot Cloud Service Access

Dataprobe offers a free iBoot Cloud Service that provides secure, centralized power control and monitoring for multiple iBoot devices from anywhere. This service simplifies management, especially for deployments with numerous iBoot units across different locations.

Diagram showing iBoot devices connected to a cloud service, controlled by a user via a computer

Figure 4: iBoot Cloud Service for centralized management.

  • Register your iBoot-G2+ with the iBoot Cloud Service.
  • Manage devices, view status, and perform power operations through a single web grensesnitt.

Sanntidsvarsler

The iBoot-G2+ can send instant notifications via email or SMS for various events, including power status changes, automatic reboots, or network connectivity issues. This keeps you informed about the status of your connected equipment and the iBoot-G2+ itself.

  • Configure alert recipients and notification types in the web grensesnitt.
  • Customize which events trigger alerts.

Vedlikehold

The iBoot-G2+ is designed for reliable, low-maintenance operation. Regular maintenance primarily involves ensuring proper ventilation and keeping the unit clean.

  • Rengjøring: Bruk en myk, tørr klut til å rengjøre utsiden av enheten. Ikke bruk flytende rengjøringsmidler eller løsemidler.
  • Ventilasjon: Ensure the unit is placed in an area with adequate airflow to prevent overheating. Do not block ventilation openings.
  • Fastvareoppdateringer: Periodically check the Dataprobe website for firmware updates. Firmware updates can provide new features, performance improvements, and security enhancements. Follow the instructions provided with the firmware update package carefully.

Feilsøking

Vanlige problemer og løsninger

ProblemMulig årsakLøsning
iBoot-G2+ not accessible via web grensesnitt.Incorrect IP address, network cable disconnected, DHCP issue, unit not powered on.Verify power and network cable connection. Use the iBoot Discovery Tool to find the IP address. Check router's DHCP client list. Ensure the unit is powered on (Outlet On LED should be lit).
Connected device does not power cycle.Device not properly plugged into iBoot-G2+ output, iBoot-G2+ not receiving power, AutoPing not configured correctly.Ensure the device is securely plugged into the A/C Output. Check iBoot-G2+ power. Review AutoPing settings in the web interface (target IP, ping interval, retry count).
AutoPing not working as expected.Incorrect target IP, network firewall blocking pings, device being pinged is truly unresponsive.Double-check the target IP address. Ensure no firewall rules are blocking ICMP (ping) traffic from the iBoot-G2+. Confirm the target device is indeed unresponsive.
Programmatic control (e.g., via command-line tool) is unreliable.Network latency, firewall issues, software version incompatibility.Ensure stable network connection. Check firewall settings on both the iBoot-G2+ and the controlling machine. Verify you are using the latest version of the control software. Consider using the web interface for critical operations if programmatic control is unstable.
Hostname not registering with DNS.Device firmware limitation, network DNS configuration.Access the device via its IP address directly. Check Dataprobe's support resources for firmware updates that may address this. Ensure your DNS server is configured to accept dynamic updates if applicable.

For further assistance, refer to the comprehensive user manual available on the Dataprobe website or contact Dataprobe technical support.

Spesifikasjoner

TrekkDetalj
ModellnummeriBoot-G2+
MerkeDataprobe
UtgangstypeSingle NEMA 5-15 Circuit Outlet
Inngang Voltage105-125V, 60Hz, 12A Max / 210-240V, 50Hz, 10A Max (AC)
Utvidelsesporter2 I/O Ports (EXP1, EXP2)
TilkoblingEthernet (RJ45)
Dimensjoner (LxBxH)3.2 x 4.2 x 2 tommer
Vekt1 pund
FargeSvart
Første tilgjengelige dato14. januar 2013

Garantiinformasjon

Dataprobe products are manufactured to high quality standards. For detailed warranty information, including terms, conditions, and duration, please refer to the warranty statement provided with your product or visit the official Dataprobe webnettstedet. Ta vare på kjøpsbeviset for garantikrav.

Support og kontakt

For technical support, product inquiries, or additional documentation, please visit the Dataprobe official webnettstedet eller kontakt deres kundeserviceavdeling.

  • Offisiell Webnettsted: www.dataprobe.com
  • Støtteressurser: Access FAQs, downloads, and detailed user guides.
  • Kontakt: Se til website for contact numbers and email addresses for technical support.

© 2024 Dataprobe. All rights reserved.

Relaterte dokumenter - iBoot-G2+

Preview Dataprobe iBoot-G2+ / iBoot-G2S Web Brukerhåndbok for aktivert strømbryter
Denne håndboken gir omfattende instruksjoner for Dataprobe iBoot-G2+ og iBoot-G2S web-aktiverte strømbrytere. Den dekker oppsett, drift, nettverkskonfigurasjon, utvidelsesmuligheter, skytjenester og bruk av kommandolinjegrensesnitt for ekstern strømstyring og overvåking.
Preview Dataprobe iBoot-WiFi brukerhåndbok: Fjernkontroll av strøm og omstart
Omfattende brukerhåndbok for Dataprobe iBoot-WiFi, en nettverksstyrt AC-strømbryter. Lær om fjernkontroll av strøm, omstart av enhet, AutoPing, web grensesnitt, skytjenester og feilsøking.
Preview Hurtigstartveiledning for Dataprobe iBoot-G2S: Oppsett, konfigurasjon og montering
En omfattende hurtigstartveiledning for Dataprobe iBoot-G2S, med detaljer om oppsett, nettverkstilkobling og IP-adressekonfigurasjon via web nettleser eller DMU, ​​viktige sikkerhetsinstruksjoner og monteringsalternativer for vegg- eller DIN-skinneinstallasjon.
Preview Dataprobe iBoot-PDU Quick Start Guide
Quick start guide for the Dataprobe iBoot-PDU, providing instructions on setup, IP address configuration, web browser control, and essential safety information for remote power distribution.
Preview Dataprobe iBoot-DC Quick Start Guide: Setup and Configuration
Quick start guide for the Dataprobe iBoot-DC, covering setup, network connections, IP address configuration, and mounting options. Includes essential information for initial deployment.