Introduksjon
This manual provides comprehensive instructions for the installation, operation, and maintenance of the ECOELER YM2106 Wall Switch Vacancy & Occupancy Sensor. This device is designed to automatically control lighting and motor loads based on motion detection, offering energy savings and convenience. It supports both manual-on (vacancy sensor) and automatic-on (occupancy sensor) switching modes.
Viktig sikkerhetsinformasjon
WARNING: RISK OF ELECTRIC SHOCK. Improper installation can lead to serious injury or death. Always turn off power at the circuit breaker before installation or servicing. Installation should be performed by a qualified electrician or in accordance with local electrical codes.
- Les alle instruksjoner før installasjon.
- Do not install with power on.
- Kun for innendørs bruk.
- Sørg for at ledningstilkoblingene er sikre.
- Drift voltage: 120/277Vac, 60Hz.
- Neutral wire is not required for operation.
Pakkeinnhold
Kontroller at alle komponenter er til stede før installasjonen starter:
- ECOELER YM2106 Sensor Switch
- Veggplate (1)
- Skruer
- Kablingsdeksler
- Installation Instruction Manual (this document)
Spesifikasjoner
| Modellnummer | YM2106 |
| Voltage | 120/277Vac, 60Hz |
| Deteksjonstype | PIR (passiv infrarød) |
| Dekning | 180-degrees; 720-square feet |
| Innstillinger for tidsforsinkelse | 5 sekunder til 30 minutter (justerbar) |
| Ambient Light Level | Adjustable (holds lighting off when natural light is sufficient) |
| Kabling | Neutral wire not required |
| Lasttyper | Incandescent, Fluorescent, LED, CFL |
| Sertifiseringer | UL Listed, Title-24 Compliant |
| Dimensjoner | 4.12 x 1.69 x 1.75 tommer |
| Materiale | Plast og metall |
Installasjonsinstruksjoner
Før du begynner: Turn OFF power at the circuit breaker or fuse box. Ensure the power is completely disconnected before proceeding.
- Forbered ledninger: Carefully remove the existing wall switch from the electrical box. Identify the LINE (hot), LOAD, and GROUND wires. The ECOELER YM2106 does not require a neutral wire.
- Koble til ledninger:
- Koble til svart ledning fra sensoren til LINE (hot) wire from the electrical box. Secure with a wiring cap.
- Koble til rød ledning fra sensoren til LAST-ledning (to the light fixture/motor) from the electrical box. Secure with a wiring cap.
- Koble til grønn ledning fra sensoren til JORDledning from the electrical box. Secure with a wiring cap.
- Cap off any unused wires in the electrical box, such as a neutral wire, if present.
- Monter sensoren: Gently fold the wires into the electrical box. Insert the sensor into the electrical box and secure it with the provided screws.
- Installer veggplate: Attach the decorative wall plate over the sensor and secure it.
- Gjenopprett kraften: Slå PÅ strømmen ved strømbryteren.
- Testfunksjonalitet: The green LED indicator light on the sensor will flash when motion is detected, confirming active detection.
Note: If you are unsure about any wiring steps, consult a qualified electrician.
Operasjon
The ECOELER YM2106 sensor supports two primary modes of operation: Vacancy (Manual-On) and Occupancy (Automatic-On).
Vacancy Sensor (Manual-On) Mode
In this mode, the lights/motor will only turn ON when you manually press the switch button. Once ON, the sensor will keep the lights/motor ON as long as motion is detected within its coverage area. The lights/motor will turn OFF automatically after no motion is detected for the set time delay.
Occupancy Sensor (Automatic-On) Mode
In this mode, the lights/motor will turn ON automatically when motion is detected within the sensor's coverage area. The lights/motor will remain ON as long as motion is detected and will turn OFF automatically after no motion is detected for the set time delay.
To switch between modes or adjust settings, refer to the "Configuration and Settings" section.
Konfigurasjon og innstillinger
The ECOELER YM2106 sensor features adjustable settings for time delay, sensitivity, and ambient light level. These adjustments are typically made via small dials or switches located on the sensor itself, often behind the wall plate.
- Tidsforsinkelse: This setting determines how long the lights/motor remain ON after the last detected motion. It is adjustable from 5 seconds to 30 minutes. Adjust clockwise for longer delays, counter-clockwise for shorter delays.
- Følsomhet: This controls the sensor's responsiveness to motion. Higher sensitivity detects smaller movements or movements at greater distances. Lower sensitivity requires more significant motion or closer proximity. Adjust as needed to prevent false triggers or missed detections.
- Ambient Light Level (Photocell): This setting allows the sensor to hold the lights/motor OFF if sufficient natural light is present in the room, even if motion is detected. This feature helps save energy by preventing artificial lighting from turning on unnecessarily. Adjust to your desired light threshold.
Consult the diagrams on the sensor unit itself for the exact location and labeling of these adjustment controls.
Vedlikehold
- Rengjøring: Periodically wipe the sensor lens with a soft, dry cloth to remove dust or debris that may obstruct detection. Do not use abrasive cleaners or solvents.
- Undersøkelse: Regularly check the sensor and wall plate for any signs of damage or loose connections.
- Ingen deler som kan repareres av brukeren: The sensor contains no user-serviceable parts. Do not attempt to open or repair the unit.
Feilsøking
| Problem | Mulig årsak | Løsning |
|---|---|---|
| Lights/Motor do not turn ON. |
|
|
| Lights/Motor turn ON unexpectedly. |
|
|
| Lights/Motor turn OFF too quickly or too slowly. |
|
|
Garanti og støtte
For warranty information or technical support, please contact ECOELER customer service. Retain your proof of purchase for warranty claims.
Contact information is typically found on the product packaging or the manufacturer's official webnettstedet.