Jumper Medical JPD-FR301

Jumper Medical Infrared Ear Thermometer

Model: JPD-FR301 User Manual

1. Introduksjon

This user manual provides detailed instructions for the safe and effective operation of your Jumper Medical Infrared Ear Thermometer, Model JPD-FR301. This device is designed for accurate body temperature measurement in the ear canal for all ages, including infants, children, and adults.

Les denne bruksanvisningen nøye før første gangs bruk, og ta vare på den for senere referanse.

2. Produktfunksjoner

  • Digital Infrared (IR) Ear Thermometer with protective cap.
  • Fast 1-second measurement for quick results.
  • Acoustic fever alarm for elevated temperatures (> 37.5 °C).
  • Memory storage for the last 20 measurement readings.
  • Switchable temperature display between Celsius (°C) and Fahrenheit (°F).
  • Ergonomic design for comfortable handling and use.
  • High sensitivity for maximum precision.
  • Meets high hygienic standards.
  • Certified with CE, FDA, ISO 13485 + AC:2012, ISO 10993-1, ISO 10993-10, Norm IEC 60601-1-2, and conforms to the Medical Devices Directive - MDD (EU).
Jumper Medical Infrared Ear Thermometer in hand, demonstrating its ergonomic design and display.

Figur 2.1: The Jumper Medical Infrared Ear Thermometer held in a hand, showcasing its ergonomic shape and the clear LCD display.

3. Get to Know Your Product (Components)

Detailed diagram of the Jumper Medical JPD-FR301 thermometer, labeling its parts including the measuring button, LCD display, sensor, battery cover, ear cap case, and disposable ear caps.

Figur 3.1: Labeled diagram of the JPD-FR301 thermometer components.

  1. Måleknapp: Used to initiate a temperature measurement.
  2. LCD-skjerm: Viser temperaturavlesninger, modusindikatorer og batteristatus.
  3. Sensor: The infrared sensor located at the tip for accurate ear temperature detection.
  4. Batterideksel: Beskytter batterirommet.
  5. Ear cap case: Storage for disposable ear caps.
  6. Disposable ear caps: Hygienic covers for the sensor.
  7. Toppdekselet: Part of the ear cap case.
  8. Bakdeksel: Part of the ear cap case.

4. Innhold i emballasjen

Når du åpner pakken, må du kontrollere at alle varene som er oppført nedenfor er til stede og i god stand:

  • Jumper Medical Infrared Ear Thermometer unit (JPD-FR301)
  • Pouch or storage bag
  • Ear cap case with disposable ear caps
  • 2 pcs of AAA battery
All items included in the Jumper Medical Infrared Ear Thermometer package: the thermometer, a soft pink storage pouch, the ear cap dispenser, and two AAA batteries.

Figur 4.1: All items included in the product packaging.

5. Oppsett

5.1 Installasjon av batteri

Termometeret trenger to AAA-batterier for å fungere. Slik setter du inn eller bytter du batterier:

  1. Locate the battery cover (4) on the back of the thermometer.
  2. Skyv batteridekselet åpent.
  3. Sett inn to AAA-batterier, og sørg for at polariteten (+ og -) er riktig veiledet som angitt inni batterirommet.
  4. Lukk batteridekselet godt til det klikker på plass.

5.2 Attaching/Using Ear Cap Case

The ear cap case (5) holds disposable ear caps (6) for hygienic use. Always use a new, undamaged ear cap for each measurement.

Series of images demonstrating how to open the Jumper Medical ear cap case, insert disposable ear caps, and attach the case to the thermometer.

Figur 5.1: Steps for handling the ear cap case and disposable ear caps.

  1. To open the ear cap case, gently lift the top cover (7) or slide the rear cover (8).
  2. Take out a disposable ear cap.
  3. Carefully place the ear cap onto the sensor (3) of the thermometer until it is securely fitted.
  4. After use, dispose of the used ear cap properly.

6. Bruksanvisning

6.1 Ta en måling

  1. Ensure a new, clean disposable ear cap is securely attached to the sensor.
  2. Press the "START" (Measuring button 1) to turn on the thermometer. The display will show the last measurement or a standby indicator.
  3. Gently insert the sensor tip with the ear cap into the ear canal. For accurate readings, ensure the tip is pointing towards the eardrum.
  4. Press the "START" button again to initiate the measurement.
  5. The measurement will be completed in approximately 1 second, and the result will be displayed on the LCD (2).
  6. If the temperature is elevated (fever alarm), an audible alert will sound.
  7. The thermometer will automatically store the reading in its memory.
  8. Remove the thermometer from the ear and dispose of the used ear cap.

6.2 Switching Between °C and °F

To switch the temperature unit between Celsius (°C) and Fahrenheit (°F):

  • With the thermometer turned off, press and hold the "START" button for approximately 5 seconds until the unit changes on the display.
  • Release the button. The new unit will be set for future measurements.

6.3 Minnegjenkalling

The thermometer stores the last 20 measurement readings. To recall them:

  • Slå på termometeret.
  • Briefly press the "START" button repeatedly to cycle through the stored readings. Each press will display the next previous reading.

7. Vedlikehold

7.1 Rengjøring av termometeret

  • Always clean the thermometer after each use, especially the sensor area.
  • Bruk en myk klut lett dampened with 70% isopropyl alcohol to wipe the sensor and the body of the thermometer.
  • Ikke senk termometeret i vann eller annen væske.
  • Allow the thermometer to air dry completely before storing.
  • Ikke bruk skurende rengjøringsmidler eller sterke kjemikalier.

7.2 Oppbevaring

Store the thermometer in its original pouch or the ear cap case in a cool, dry place, away from direct sunlight and extreme temperatures.

Hvis termometeret ikke skal brukes over lengre tid, må du ta ut batteriene for å forhindre lekkasje og skade.

7.3 Drifts- og lagringsbetingelser

Infographic detailing the recommended operating and storage environmental conditions for the Jumper Medical thermometer, including temperature, atmospheric pressure, and humidity ranges.

Figur 7.1: Recommended environmental conditions for operation and storage.

Operating Environment Conditions:

  • Temperatur: +10°C ~ +40°C (50°F ~ 104°F)
  • Atmosfærisk trykk: 86 kPa ~ 106 kPa
  • Fuktighet: 15-85 % RF, ikke-kondenserende

Storage & Transportation Conditions:

  • Temperatur: -10°C ~ +50°C (14°F ~ 122°F)
  • Atmosfærisk trykk: 50 kPa ~ 106 kPa
  • Fuktighet: <93% RF, ikke-kondenserende

8. Feilsøking

ProblemMulig årsakLøsning
Termometeret slår seg ikke på.Batteriene er døde eller satt inn feil.Bytt batteriene med nye AAA-batterier, og sørg for at polariteten er riktig.
Unøyaktige avlesninger.Used or damaged ear cap; sensor dirty; improper insertion into ear canal; extreme environmental conditions.Use a new, clean ear cap. Clean the sensor. Ensure correct insertion. Operate within specified temperature and humidity ranges.
«Lo» eller «Hi» vises.Temperaturen er utenfor det målbare området.Ensure the thermometer is used in the correct operating temperature range and the subject's temperature is within human body temperature limits.
Feberalarmen lyder ofte.Subject's temperature is consistently above 37.5 °C (99.5 °F).This indicates an elevated temperature. Consult a medical professional if fever persists.

9. Spesifikasjoner

TrekkDetalj
Modell:JPD-FR301
Produkttype:Infrarød øre termometer
Strømkilde:2 x AAA Batteries (Battery-operated)
Målingstid:1 sekund
Minnekapasitet:20 avlesninger
Temperaturenheter:Celsius (°C) / Fahrenheit (°F) switchable
Materiale:Plast
Aldersgruppe:Child and Adult
UPC:635833227234
Sertifiseringer:CE, FDA, ISO 13485 + AC:2012, ISO 10993-1, ISO 10993-10, Norm IEC 60601-1-2, MDD (EU)
Emballasjedimensjoner:19.4 x 13.2 x 6.4 cm
Vekt:300 Grams (packaged)

10. Garanti og støtte

For warranty information or technical support, please refer to the warranty card included in your product packaging or contact Jumper Medical customer service directly. Contact details can typically be found on the manufacturer's official webnettstedet eller på produktemballasjen.

Please have your model number (JPD-FR301) and purchase information ready when contacting support.

© 2024 Jumper Medical. All rights reserved.

Denne håndboken kan endres uten varsel.