1. Viktige sikkerhetsinstruksjoner
Before using the appliance, read these safety instructions carefully. Keep them for future reference. The appliance is designed for domestic use only.
- Never vacuum liquids: Do not use the vacuum cleaner to pick up water or any other liquids. This can cause electric shock or damage to the appliance.
- Avoid flammable substances: Never use the vacuum cleaner near flammable or combustible substances, such as gasoline, or in areas where they may be present.
- Hose inspection: Regularly check the hose for damage. Do not use the appliance if the hose is damaged.
- Elektrisk sikkerhet: Ensure the power cord is not damaged. If the cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.
- Children and supervision: Dette apparatet kan brukes av barn i alderen 8 år og oppover og personer med reduserte fysiske, sensoriske eller mentale evner eller mangel på erfaring og kunnskap hvis de har fått tilsyn eller instruksjoner om bruk av apparatet på en sikker måte og forstår farene involvert. . Barn skal ikke leke med apparatet. Rengjøring og brukervedlikehold skal ikke utføres av barn uten tilsyn.
2. Produktet er overview
The AEG VX6-2-IW-5 is a powerful and maneuverable bagged vacuum cleaner designed for efficient cleaning on various floor types. It features 360° rotating wheels, an ergonomic handle, and a 9-meter operating radius.

Bilde: Topp view of the AEG VX6-2-IW-5 vacuum cleaner, highlighting the power button, cord rewind button, and suction control dial. The 'OPEN' latch for bag access is also visible.

Image: The AEG VX6-2-IW-5 vacuum cleaner fully assembled with its flexible hose, telescopic tube, and standard floor nozzle, ready for use.
3. Oppsett og montering
- Pakk ut komponenter: Carefully remove all components from the packaging. Ensure all included items are present: the main vacuum unit, hose, telescopic tube, DustPro floor nozzle, joint and upholstery nozzle, 5 Classic Long Performance dust bags, and the washable Hygiene Filter (pre-installed).
- Fest slangen: Insert the hose connector firmly into the suction inlet on the main vacuum unit until it clicks into place.
- Monter teleskoprøret: Connect the telescopic tube to the handle end of the hose. Adjust the length of the telescopic tube by pressing the release button and sliding it to your desired height.
- Fest gulvmunnstykket: Connect the DustPro floor nozzle to the end of the telescopic tube. Ensure it is securely attached.
- Install Dust Bag and Filter: The vacuum cleaner comes with a dust bag and washable Hygiene Filter pre-installed. To check or replace, open the 180° access lid on the top of the unit. Refer to the 'Maintenance' section for detailed instructions on replacing the dust bag and cleaning the filter.
- Fest tilbehør: The 2-in-1 joint and upholstery nozzle can be attached to the handle for convenient access during cleaning.
4. Bruksanvisning
4.1 Slå på og av
- Koble til strøm: Extend the power cord and plug it into a suitable electrical outlet. The vacuum has a 9-meter action radius for multi-room cleaning.
- Strøm på: Press the power button (marked with 'I') located on the top of the vacuum cleaner.
- Slå av: Trykk på av/på-knappen igjen for å slå av apparatet.
- Spol tilbake: After use, press the cord rewind button (marked with a plug symbol) to automatically retract the power cord.
4.2 Sugekontroll
The vacuum cleaner features continuous suction control, allowing you to adjust the suction power for different cleaning tasks and surfaces.

Image: A hand rotating the central dial on the vacuum cleaner, which controls the suction power. The dial has '+' and '-' indicators for increasing eller dekresjonasing suction.
- Justering av sugekraft: Rotate the central dial on the top of the unit to increase or decrease suction power.
- Anbefalte innstillinger: For general cleaning, adjust the dial to a comfortable level. For delicate surfaces or light fabrics, reduce suction. For heavily soiled carpets or hard floors, increase suction.
4.3 Rengjøringsytelse
The powerful motor and high-efficiency floor nozzle ensure thorough cleaning results on both hard floors and carpets.

Image: The floor nozzle of the AEG VX6-2-IW-5 vacuum cleaner effectively picking up scattered debris from a dark wooden floor, demonstrating its cleaning capability.

Image: A person using the AEG VX6-2-IW-5 vacuum cleaner to clean a light-colored carpet in a modern living room, with the vacuum unit positioned on the floor.
- Harde gulv: Use the DustPro floor nozzle with the brush setting engaged (if applicable) for optimal cleaning on hard surfaces.
- Tepper: For carpets, ensure the brush setting is retracted (if applicable) to allow for maximum suction and smooth gliding.
- Manøvrerbarhet: The 360° rotating soft wheels and ergonomic handle provide excellent mobility, allowing you to navigate around furniture and obstacles with ease.
5. Vedlikehold
Regelmessig vedlikehold sikrer optimal ytelse og forlenger levetiden til støvsugeren din.
5.1 Utskifting av støvpose
The vacuum cleaner uses 3.5-liter Classic Long Performance dust bags. Replace the dust bag when the dust bag indicator is full or when suction power noticeably decreases.
- Access the Dust Bag: Ensure the vacuum cleaner is unplugged. Press the 'OPEN' latch on the top of the unit to lift the 180° access lid.
- Fjern den gamle posen: Carefully pull the cardboard collar of the full dust bag upwards to seal the opening and remove it from the bag holder. Dispose of the bag responsibly.
- Sett inn ny pose: Slide a new Classic Long Performance dust bag into the bag holder, ensuring the cardboard collar is fully seated.
- Lukk lokket: Close the 180° access lid firmly until it clicks into place.

Image: A hand demonstrating the process of replacing a dust bag and the washable Hygiene Filter within the AEG VX6-2-IW-5 vacuum cleaner, with the top lid open.
5.2 Rengjøring og utskifting av filter
The vacuum cleaner is equipped with a washable Allergy Plus Filter (HEPA Filter). Regular cleaning of the filter is crucial for maintaining suction power and air quality.
- Tilgang til filteret: With the 180° access lid open (as for dust bag replacement), locate the filter.
- Fjern filter: Carefully lift the filter out of its compartment.
- Rengjør filter: Tap the filter gently over a waste bin to remove loose dust. If heavily soiled, rinse the filter under lukewarm running water. Do not use detergents.
- Tørt filter: Allow the filter to air dry completely for at least 24 hours before reinserting. Do not dry in direct sunlight or with heat.
- Sett inn filteret på nytt: Once completely dry, place the filter back into its compartment, ensuring it is correctly seated.
- Filterbytte: The Allergy Plus Filter should be replaced approximately once a year, or more frequently depending on usage. Use genuine AEG replacement filters (e.g., ASKVX8 performance kit).
5.3 Nozzle and Hose Cleaning
- Gulvmunnstykke: Periodically check the floor nozzle for tangled hair, threads, or debris. Remove any obstructions to ensure effective cleaning.
- Slange: Inspect the hose for blockages. If a blockage is suspected, disconnect the hose from the vacuum and carefully remove the obstruction using a blunt object. Never use sharp objects that could puncture the hose.
6. Feilsøking
If you encounter issues with your AEG VX6-2-IW-5 vacuum cleaner, refer to the following common problems and solutions.
| Problem | Mulig årsak | Løsning |
|---|---|---|
| Ingen strøm | Power cord not plugged in; no power at outlet; damaged power cord. | Check power cord connection; test outlet with another appliance; contact service if cord is damaged. |
| Tap av sug | Dust bag full; filter clogged; hose or nozzle blocked. | Replace dust bag; clean/replace filter; check and clear blockages in hose/nozzle. |
| Uvanlig støy | Foreign object in fan or motor; blockage in hose/nozzle. | Turn off and unplug. Inspect for foreign objects. Clear any blockages. If noise persists, contact service. |
| Cord will not rewind | Cord is tangled or mechanism is jammed. | Pull out a small amount of cord and try rewinding again. Guide the cord manually if necessary. Do not force. If issue persists, contact service. |
7. Spesifikasjoner
| Trekk | Spesifikasjon |
|---|---|
| Modellnavn | VX6-2-IW-5 |
| Merke | AEG |
| Strømkilde | Elektrisk med ledning |
| Wattage | 800 watt |
| Voltage | 230 volt |
| Ampslette | 3.48 Amps |
| Kapasitet | 3.5 Liters (Dust Bag) |
| Filtertype | HEPA Filter (Washable Allergy Plus Filter) |
| Støynivå | 76 desibel |
| Overflateanbefaling | Teppe, hardt gulv |
| Handlingsradius | 9 meter |
| Varevekt | 4.26 kilo |
| Varedimensjoner (L x B x H) | 17.36 cm x 11.54 cm x 9.37 cm |
| Antall hjul | 4 (360° rotating soft wheels) |
| Inkluderte komponenter | Floor Vacuum Cleaner VX6 with Pouch, DustPro Floor Nozzle, Washable Hygiene Filter, Joint and Upholstery Nozzle, 5 Classic Long Performance Dust Bags |
| Tilkoblingsteknologi | Wi-Fi (Note: This feature may refer to internal system diagnostics or smart home integration, consult manufacturer for details) |
8. Garantiinformasjon
AEG products are manufactured to high quality standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official AEG webnettstedet. Ta vare på kjøpsbeviset for eventuelle garantikrav.
9. Kundestøtte
For further assistance, technical support, or to order replacement parts and accessories, please contact AEG customer service. Contact details can typically be found on the official AEG webnettstedet eller i dokumentasjonen som følger med produktet.
- Offisiell Webnettsted: www.aeg.com (Sjekk din region webstedet)
- Accessory Recommendation: Performance kit ASKVX8, Dust bag GR201, SpeedyClean Hard Floor Nozzle AP350, BedPro Mattress Nozzle AZE123.