1. Introduksjon
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Sentiotec K1 Sauna Control Unit. Please read these instructions carefully before installation and use, and retain them for future reference. The Sentiotec K1 features innovative K1-Next Technology, offering a monobloc housing with integrated controls for a seamless sauna experience.
2. Sikkerhetsinstruksjoner
ADVARSEL: Fare for elektrisk støt og brann!
- Installation and electrical connections must be performed by a qualified electrician in accordance with all local and national electrical codes.
- Ensure the main power supply to the sauna heater and control unit is disconnected before any installation, maintenance, or troubleshooting.
- Do not operate the control unit if it is damaged or malfunctioning.
- Keep the control unit dry and away from direct water spray.
- Dette apparatet er ikke beregnet for bruk av personer (inkludert barn) med reduserte fysiske, sensoriske eller mentale evner, eller mangel på erfaring og kunnskap, med mindre de har fått tilsyn eller instruksjoner om bruk av apparatet av en person som er ansvarlig for deres sikkerhet.
- Barn bør overvåkes for å sikre at de ikke leker med apparatet.
3. Produktet er overview
The Sentiotec K1 Sauna Control Unit is designed for intuitive control of your sauna heater and lighting. It features a compact, monobloc design with clearly marked controls.

This image displays the Sentiotec K1 Sauna Control Unit. The unit features a two-tone design, with a dark gray upper panel and a white lower panel. On the left side of the dark gray panel, there are two white push-buttons. The top button is marked with a power symbol (circle with a vertical line), and the bottom button is marked with a light bulb symbol. On the right side, there is a large white rotary knob for temperature adjustment, with a temperature scale indicated around its circumference and a thermometer icon above it. The overall design is clean and functional.
Kontrollelementer:
- På-knapp (⏻): Activates and deactivates the sauna heater.
- Lysknapp (☼): Controls the sauna cabin lighting.
- Temperaturkontrollknapp: Adjusts the desired sauna temperature.
4. Installasjon
Professional installation by a qualified electrician is mandatory.
4.1. Monteringssted
- Mount the control unit outside the sauna cabin, in a dry, easily accessible location.
- Sørg for tilstrekkelig ventilasjon rundt enheten.
- Avoid locations exposed to direct sunlight or extreme temperatures.
4.2. Elektrisk forbindelse
- The unit requires a supply voltage of 400 V 3 N ~.
- Connect the sauna heater, temperature sensor, and light according to the wiring diagram provided with the product packaging.
- Sørg for at alle koblinger er sikre og ordentlig isolert.
- The control unit includes temperature and safety sensors for the oven. These must be correctly installed within the sauna heater.
- Maximum load capacity for the heater is 9.0 kW.
5. Drift
The Sentiotec K1 allows for simple and precise control of your sauna environment.
5.1. Slå på/av
- To turn on the sauna heater, press the Strømknapp (⏻).
- To turn off the sauna heater, press the Strømknapp (⏻) igjen.
5.2. Justering av temperatur
- Roter Temperaturkontrollknapp to set the desired sauna temperature.
- The temperature can be continuously adjusted from 40 °C to 125 °C.
- The maximum temperature displayed is 125 °C.
5.3. Controlling Sauna Light
- Trykk på Lysknapp (☼) to turn the sauna cabin light on or off.
5.4. Heating Time Limit
- The control unit has a fixed heating time limit of 6 hours. After this period, the heater will automatically shut off for safety.
6. Vedlikehold
Regular maintenance ensures the longevity and proper functioning of your control unit.
- Sørg for at strømforsyningen er frakoblet før rengjøring.
- Wipe the surface of the control unit with a soft, damp klut. Ikke bruk skurende rengjøringsmidler eller løsemidler.
- Do not allow water to enter the unit.
- Kontroller regelmessig alle elektriske tilkoblinger for tetthet og tegn på slitasje.
7. Feilsøking
The Sentiotec K1 is equipped with an optical error indicator to assist in diagnosing issues.
- No Power / Unit Unresponsive: Check the main power supply to the sauna and the control unit. Verify all electrical connections.
- Varmeapparatet aktiveres ikke: Ensure the temperature setting is above the current sauna temperature. Check for any error indicators.
- Optical Error Indicator Active: The unit features an optical error indicator. This may signal a sensor break or a short circuit. In such cases, the unit will automatically shut down.
- Unit Shuts Down Unexpectedly: This could be due to the 6-hour heating time limit or a safety shutdown triggered by a sensor issue (break or short circuit).
If problems persist after checking these points, contact a qualified electrician or Sentiotec customer support.
8. Spesifikasjoner
| Trekk | Spesifikasjon |
|---|---|
| Merke | Sentiotec |
| Modell | K1 |
| Forsyning Voltage / Fase | 400 V 3 N ~ |
| Dimensjoner (enhet) | 236 x 90 x 195 mm |
| Temperaturjusteringsområde | 40 – 125 °C |
| Maksimal belastning | 9.0 kW |
| Heating Time Limit | 6 timer |
| Lyskontroll | Ja |
| Ventilasjonskontroll | Ingen |
| Smarttelefonkontroll | Ingen |
| Varevekt | 5 kilo |
| Avviklet av produsent | Ingen |
9. Garanti og støtte
For warranty information, please refer to the documentation included with your purchase or contact your retailer. For technical support or inquiries, please visit the official Sentiotec webnettstedet eller kontakt deres kundeserviceavdeling.