1. Introduksjon

This manual provides essential information for the safe and efficient operation of your Green Cell Off Grid Inverter with MPPT Solar Charger, model INVSOL03. This device integrates an inverter, MPPT solar charger, and battery charger functions to offer an uninterruptible power supply solution. Please read this manual thoroughly before installation and use, and retain it for future reference.

2. Sikkerhetsinstruksjoner

Always observe the following safety precautions to prevent injury and damage to the inverter or connected equipment:

  • Installasjonen må utføres av kvalifisert personell.
  • Ensure all wiring is correctly sized and properly insulated.
  • Ikke utsett omformeren for regn, snø, sprut eller andre væsker.
  • Ikke demonter omformeren. Det er ingen deler inni som brukeren kan reparere.
  • Sørg for tilstrekkelig ventilasjon rundt omformeren for å forhindre overoppheting.
  • Connect the inverter to a properly grounded electrical system.
  • Before any maintenance or cleaning, disconnect all power sources (AC, DC, and PV).

3. Produktet er overview

The Green Cell INVSOL03 is a multi-functional inverter designed for off-grid applications, combining the capabilities of a solar charger, battery charger, and inverter into one unit. It provides a pure sine wave output, suitable for sensitive electronics.

3.1 Frontpanel og skjerm

Front panel of the Green Cell Off Grid Inverter showing the LCD display and control buttons.

Figure 1: Front panel with LCD display and control buttons (Menu, Up, Down, Enter).

The LCD display provides real-time information on input voltage, battery status, output load, and operational modes. The control buttons allow for navigation through menus and setting adjustments.

3.2 Tilkoblingsporter

Topp og bunn views of the Green Cell Off Grid Inverter showing various connection ports.

Figur 2: Topp og bunn views of the inverter, highlighting AC input/output, DC input, PV input, and communication ports (COM, USB).

The inverter features dedicated terminals for AC input, AC output, DC battery input, and PV (solar panel) input. Communication ports (COM, USB) are available for monitoring and configuration.

3.3 Systemdiagram

Diagram illustrating the connection of the Green Cell Off Grid Inverter to solar panels, battery, and various loads.

Figur 3: Eksample system setup showing solar panels, battery, inverter, and connected devices.

This diagram illustrates a typical setup where solar panels charge the battery via the inverter's MPPT controller, and the inverter supplies AC power to household appliances from the battery or directly from solar.

4. Oppsett

Follow these steps for proper installation of your Green Cell Off Grid Inverter:

  1. Montering: Choose a suitable location indoors, away from direct sunlight, moisture, and flammable materials. Ensure sufficient clearance for ventilation. Mount the inverter vertically on a solid surface.
  2. Batteritilkobling: Connect the battery bank to the DC input terminals. Ensure correct polarity (+ to + and - to -). Use appropriate cable gauges and fuses. The inverter is designed for a 24VDC battery system.
  3. Tilkobling til solcellepanel: Connect the solar panel array to the PV input terminals. Observe correct polarity and ensure the open-circuit voltage (Voc) and short-circuit current (Isc) of your solar array are within the inverter's specifications.
  4. AC Input Connection (Optional): If using a grid or generator as a backup, connect the AC input to the designated terminals. Ensure proper grounding.
  5. AC-utgangstilkobling: Connect your AC loads (appliances) to the AC output terminals. Ensure the total load does not exceed the inverter's rated output power.
  6. Kommunikasjonstilkoblinger: For monitoring and advanced settings, connect a USB cable to a computer or use the COM port for other communication devices.

After all connections are secure, you can proceed to power on the system.

Green Cell Off Grid Inverter mounted on a wall, connected to an electric vehicle charging station.

Figur 4: Eksample installation of the inverter in a garage setting, connected to an EV charger.

5. Bruksanvisning

Once installed, the inverter operates largely automatically. Here are key operational aspects:

5.1 Slå på/av

  • For å slå på: Ensure all connections are correct. Turn on the battery breaker first, then the PV breaker (if applicable), and finally the AC input breaker (if applicable). Press and hold the power button on the inverter until the display illuminates.
  • Slik slår du av: Disconnect AC loads. Turn off the AC input breaker, then the PV breaker, and finally the battery breaker. Press and hold the power button until the display turns off.

5.2 LCD-skjerm og innstillinger

Use the MENU, UP, DOWN, and ENTER buttons to navigate through the display screens and adjust settings. The display shows:

  • Inngang voltage (PV and AC)
  • Batteri voltage and charge status
  • Utgang voltage og belastningsprosenttage
  • Operating mode (e.g., Line Mode, Battery Mode, Fault)

Refer to the detailed settings section in the full product manual for advanced configuration options such as battery type, charging current, and output voltage rekkevidde.

5.3 Overvåkingsprogramvare

Laptop screen displaying monitoring software for the Green Cell MPPT Solar Inverter.

Figure 5: Monitoring software interface on a laptop, showing real-time data and system parameters.

The inverter can be connected to a computer via USB for detailed monitoring and data logging. The monitoring software provides a graphical interface to view system performance, historical data, and adjust advanced parameters.

6. Vedlikehold

Regular maintenance ensures optimal performance and longevity of your inverter:

  • Rengjøring: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
  • Tilkoblinger: Annually check all electrical connections for tightness and corrosion. Loose connections can cause overheating and poor performance.
  • Batteriinspeksjon: Regularly inspect your battery bank for signs of damage, corrosion, or swelling. Ensure battery terminals are clean and tight.
  • Miljø: Sørg for at driftsmiljøet holder seg innenfor de angitte temperatur- og fuktighetsområdene.

7. Feilsøking

Hvis du støter på problemer, kan du se følgende vanlige problemer og løsninger:

ProblemMulig årsakLøsning
Ingen utgangseffektBattery low; Inverter off; Overload; Fault conditionSjekk batterivoltage; Turn on inverter; Reduce load; Check fault codes on display.
Inverter beepingLow battery; Overload; Over-temperatureCheck battery; Reduce load; Ensure proper ventilation.
Solcellelading fungerer ikkePV connection issue; Insufficient sunlight; PV voltage for lav/høyCheck PV wiring and polarity; Ensure panels are clean and unshaded; Verify PV voltage er innenfor rekkevidde.
AC input not recognizedAC input breaker off; Loose connection; AC input voltage utenfor rekkeviddeCheck AC input breaker; Secure connections; Verify AC input voltage.

If the problem persists after attempting these solutions, contact Green Cell customer support.

8. Spesifikasjoner

Key technical specifications for the Green Cell Off Grid Inverter (INVSOL03):

TrekkSpesifikasjon
ModellnummerINVSOL03
Utgangseffekt2000 watt
Maksimal utgangseffekt4000 watt
Utgang Voltage230 Volt vekselstrøm
Inngang Voltage (DC)24 volt likestrøm
BølgeformRen sinusbølge
Effektivitet90 %, 93 %
Produktdimensjoner27.2 x 35.5 x 10 cm
Varevekt8.5 kg
Inkluderte komponenterMPPT controller, Inverter, Battery charger
EnergikildeSolenergi
Anbefalte applikasjonerOff-grid power supply, Solar energy storage, Emergency power backup

9. Garanti og støtte

Green Cell products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your product or visit the official Green Cell website. For technical support, troubleshooting assistance, or service inquiries, please contact Green Cell customer service through their official channels.

Ask a question about this manual