1. Produktet er overview
The OWON HDS241 is a versatile 3-in-1 handheld device integrating a single-channel oscilloscope, a 24000-count digital multimeter, and a 100kHz signal generator. Designed for both outdoor and indoor use, it offers a compact form factor with powerful measurement capabilities for various electrical and electronic applications.

Image 1.1: The OWON HDS241 device, highlighting its oscilloscope, multimeter, and signal generator functions.
2. Sikkerhetsinformasjon
Before using the OWON HDS241, please read and understand all safety instructions to prevent electric shock, injury, or damage to the device. Keep this manual for future reference.
- Generell sikkerhet: Always use the device within its specified voltage and current limits. Do not operate the device in wet or damp forhold.
- Probesikkerhet: Ensure probes are correctly connected and rated for the measurement being performed. Avoid touching exposed wiring or components when the device is powered on.
- Batterisikkerhet: Use only the specified battery type. Do not disassemble, crush, or expose the battery to extreme temperatures.
- Vedlikehold: Overlat all service til kvalifisert personell. Ikke forsøk å reparere enheten selv.
3. Nøkkelfunksjoner
- Digitalt multimeter: 4 1/2 digit True RMS digital multimeter for measuring AC/DC voltage/current, resistance, diode, capacitance, and continuity. Maximum input voltage is AC 750V, DC 1000V.
- Signal Waveform Generator: 1-channel 100 kHz generator supporting sine, square, ramp, and pulse wave outputs. Maximum output amplitude is 2.5 Vpp.
- Oscilloskop: Waveform refresh rate up to 10,000 wfms/s, 40MHz bandwidth, and real-time sampling rate up to 250MSa/s. Features auto-setup, multiple measurement functions, 8K record length, cursor measurement, and slow scan mode for long-term signal monitoring.
- Kompakt design: Portable form factor with a 3.5-inch high-definition color LCD screen, suitable for various environments.
- Lang batterilevetid: Low-power design with a 2000 mAh high-capacity lithium battery and standard Type-C port for charging and power bank compatibility.
4. Pakkens innhold
The standard package for the OWON HDS241 includes:
- OWON HDS241 Handheld Oscilloscope Unit
- Test Leads for Multimeter
- Oscilloskop Probe
- USB Type-C-kabel
- Brukerhåndbok (dette dokumentet)
Note: Additional accessories such as a BNC-to-alligator clip cable or carrying case may need to be purchased separately.
5. Enhetsoppsett og kontroller
Familiarize yourself with the physical components and controls of the HDS241.

Bilde 5.1: Forside og side view of the OWON HDS241 with key controls and ports labeled. Labels include: signal input connector, display area, multifunction keys, channel key, mode switching key, system settings, save settings, power button, relative value/activation menu key, multimeter input port, horizontal time base setting/signal adjustment, return key, range switch/measurement menu key, arrow keys, auto range/auto setting key, hold value/Stop/Run key, probe compensation output (2.5V/1kHz square wave or signal generator output), USB charging/communication interface, approximate weight (0.6 kg host, excluding battery), gross weight (1.2 kg).

Image 5.2: Detail of the BNC connector, designed for safety and signal integrity, with external rubber coating.
6. Første oppsett
6.1 Lading av enheten
The HDS241 is equipped with a built-in 2000 mAh lithium battery. Before first use, fully charge the device using the provided USB Type-C cable and a compatible power adapter (not included) or a computer USB port.
- Connect the USB Type-C cable to the device's Type-C port.
- Koble den andre enden av kabelen til en USB-strømkilde.
- Ladeindikatoren vil vise ladestatusen.

Image 6.1: The USB Type-C charging port and internal battery compartment, emphasizing long-lasting performance.
6.2 Slå på/av
Trykk og hold inne Makt knappen for å slå enheten på eller av.
7. Driftsmåter
The HDS241 features three primary operating modes: Oscilloscope, Multimeter, and Signal Generator. Press the Modus -knappen for å veksle mellom disse funksjonene.
7.1 Oscilloskopmodus
In Oscilloscope mode, the device displays real-time waveforms, allowing for detailed analysis of electrical signals. Connect the oscilloscope probe to the BNC connector on the top of the device.
- Auto-Setup: Trykk på Auto button for automatic scaling and positioning of the waveform.
- Mål: Bruk Måle menu (accessed via F1) to select automatic measurements like Frequency, Period, Amplitude, Max, Min, Peak-to-Peak, and RMS.
- Markørmål: Activate cursor measurements (accessed via F2) to manually measure voltage (ΔV) and time (ΔT) differences between points on the waveform.
- Utløserinnstillinger: Adjust trigger type, level, and mode using the Trig/Δ knapp.
- Horizontal/Vertical Controls: Use the navigation arrows to adjust time base (horizontal) and voltage scale (vertical).

Bilde 7.1.1: Eks.amples of oscilloscope display features including dual sampling mode, high refresh rate, 8 types of auto-measurements, and cursor measurements.

Bilde 7.1.2: Eks.amples of actual measured waveforms, demonstrating the oscilloscope's signal capture capabilities for different signal types.
7.2 Multimetermodus
In Multimeter mode, the HDS241 functions as a digital multimeter. Connect the test leads to the appropriate input ports (VΩ+C, COM, A, mA) at the bottom of the device.
- Funksjonsvalg: Bruk Modus button to cycle through measurement types (Voltage, Current, Resistance, Capacitance, Diode, Continuity).
- Automatisk rangering: The device supports auto-ranging for convenient measurement.
- Data Hold: Bruk Spare button or a dedicated hold function (if available) to freeze the current reading.
7.3 Signalgeneratormodus
The Signal Generator mode allows the device to output various waveforms. Connect the output to the circuit under test using the appropriate cable (e.g., BNC to alligator clips, not included).
- Valg av bølgeform: Use the F-keys to select sine, square, ramp, or pulse waveforms.
- Parameterjustering: Adjust frequency and amplitude using the navigation arrows. The maximum output amplitude is 2.5 Vpp.
8. Databehandling
The HDS241 supports data transfer to a computer via its USB Type-C port for further analysis and record-keeping.
- Koble til PC: Use the provided USB Type-C cable to connect the device to your computer.
- Programvare: Refer to the OWON website for any necessary drivers or software to facilitate data transfer and analysis.
- Lagre data: Bruk Spare button to store waveform images, settings, or measurement data directly on the device.

Image 8.1: The OWON HDS241 connected to a computer for data transfer and analysis, enabling easy waveform control.
9. Vedlikehold
- Rengjøring: Rengjør enheten med en myk, tørr klut. Ikke bruk slipende rengjøringsmidler eller løsemidler.
- Lagring: Oppbevar enheten på et kjølig og tørt sted, unna direkte sollys og ekstreme temperaturer.
- Batteripleie: For long-term storage, ensure the battery is partially charged (around 50%) and recharge it every few months to maintain battery health.
- Probekalibrering: Periodically calibrate the oscilloscope probe using the dedicated probe compensation output to ensure accurate measurements.
10. Feilsøking
| Problem | Mulig årsak | Løsning |
|---|---|---|
| Enheten slås ikke på. | Lavt eller utladet batteri. | Connect the device to a power source using the USB Type-C cable and allow it to charge. |
| Ingen bølgeform vises i oscilloskopmodus. | Probe not connected correctly; signal too small or too large; incorrect time base or voltage skala. | Ensure probe is securely connected. Press Auto for automatic setup. Adjust vertical and horizontal scales manually. Check trigger settings. |
| Multimeteravlesningene er unøyaktige. | Test leads not properly connected; incorrect measurement function selected; external interference. | Verify test lead connections. Ensure the correct measurement mode (voltage, current, resistance) is selected. Minimize external electrical noise. |
| Signal generator output is not as expected. | Incorrect waveform type, frequency, or amplitude set. | Check the selected waveform, frequency, and amplitude settings in the signal generator menu. |
11. Tekniske spesifikasjoner
Oscilloskopspesifikasjoner:
| Parameter | Verdi |
|---|---|
| Båndbredde | 40 MHz |
| Kanal | 1 |
| Sampling rate | 250MSa / s |
| Oppkjøpsmodus | Sample, Peak Detect |
| Rekordlengde | Max. 8K |
| Utstilling | 3.5 tommers LCD |
| Oppdateringsfrekvens for bølgeform | 10,000 XNUMX wfms/s |
| Inngangskobling | DC, AC, Ground |
| Inngangsimpedans | 1 MΩ±2%, in parallel with 16 pF±10 pF |
| Sondedemping | 1X, 10X, 100X, 1000X |
| Max Input Voltage | 400V (DC + AC, PK-PK) |
| Sensitivity Resolution | 10mV/div-10V/div |
| Vertikal oppløsning | 8 bit |
| Horisontal skala | 5ns/div-1000s/div, step 1-2-5 |
| Trigger Type | Kant |
| Utløsermodus | Auto, Normal, Single |
| Automatisk måling | Period, Frequency, Mean, PK-PK, Max, Min, Amplitude, RMS |
| Markørmåling | ΔV, ΔT |

Image 11.1: Detailed oscilloscope specifications.
Digital Multimeter Specifications:
| Parameter | Verdi |
|---|---|
| Antall visninger | 4½ digits (max 24000 counts) |
| Testmoduser | Voltage, Current, Resistance, Capacitance, Diode, Continuity |
| Max Input Voltage | AC 750V, DC 1000V |
| Maks inngangsstrøm | AC 10A, DC 10A |
| Auto rekkevidde | Ja |
| Ekte RMS | Ja |

Image 11.2: Detailed digital multimeter specifications.
Signal Waveform Generator Specifications:
| Parameter | Verdi |
|---|---|
| Bølgeformer | Sine, Square, Ramp, Puls |
| Utgangsfrekvens | 10Hz-100KHz |
| Amplitude | 2Vpp-2.5Vpp |

Image 11.3: Detailed signal waveform generator specifications.
Generelle spesifikasjoner:
- Dimensjoner: 9.6 x 3.8 x 19.8 cm
- Varevekt: 1.2 kilo
- Strømkilde: Batteridrevet (2000 mAh litiumbatteri)
- Farge: Blå
- Sertifiseringer: CE, True RMS
12. Garanti og støtte
OWON products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the official OWON webnettstedet eller kontakt din lokale distributør.
- Garantiperiode: Standard manufacturer's warranty applies. Please check your purchase documentation for specific terms and duration.
- Teknisk støtte: Visit the OWON official website for FAQs, software downloads, and contact information for technical assistance.
- Returnerer: Refer to the retailer's return policy for details on product returns and exchanges.