YUHANUS 767637528832

YUHANUS 600lbs Inswinging Magnetic Door Access Control System User Manual

Modell: 767637528832

1. Produktet er overview

The YUHANUS 600lbs Inswinging Magnetic Door Access Control System provides a secure and convenient solution for managing door access. This kit is designed for inswinging doors and includes all necessary components for installation and operation, featuring a powerful magnetic lock, a robust power supply controller, a stainless steel exit button, and remote control functionality.

2. Sikkerhetsinformasjon

  • Elektrisk sikkerhet: Ensure all power connections are made by a qualified professional. Disconnect power before performing any installation or maintenance.
  • Riktig installasjon: Incorrect installation can compromise security and product functionality. Follow all instructions carefully.
  • Ventilasjon: Ensure the power supply unit is installed in a well-ventilated area to prevent overheating.
  • Magnetfelt: Keep magnetic-sensitive devices away from the magnetic lock to avoid interference.

3. Hva er inkludert

The YUHANUS 600lbs Inswinging Magnetic Door Access Control System includes the following components:

  • 600lbs Magnetic Lock
  • Door Power Supply Controller
  • Stainless Steel Exit Button
  • Remote Controller (Fob)
  • Remote Control Receiver Module
  • ZL Bracket for Inswinging Doors
  • Strømpluggkontakt
Diagram of the YUHANUS 600lbs Inswinging Magnetic Door Access Control System components and their general setup.

Figur 3.1: Overview of the Access Control System Components

4. Components Details

4.1. 600lbs Magnetic Lock

This electromagnetic lock provides 600 pounds of holding force, ensuring secure door closure. It features a built-in alarm beeper that activates if the door is not securely locked after a set delay.

Detaljert view of the 600lbs magnetic lock with dimensions.

Figure 4.1: Magnetic Lock with Dimensions

4.2. Door Power Supply Controller

The power supply unit converts AC 110V-240V to DC 12V (4A) and manages the lock's operation, including timing for the alarm and connections for other components. It is designed for hardwired electrical connection.

Front view of the power supply controller showing input/output terminals and caution label.

Figure 4.2: Power Supply Controller

4.3. Stainless Steel Exit Button

A durable push-to-exit button for convenient egress from the secured area. It is constructed from high-quality stainless steel for longevity.

Detaljert view of the stainless steel exit button with dimensions.

Figure 4.3: Exit Button

4.4. Remote Controller and Receiver

The system includes a remote control fob and a receiver module, allowing for wireless unlocking of the door from up to 165 feet away.

Image of the remote control fob.Innvendig view of the remote control receiver module.

Figure 4.4: Remote Control Fob and Receiver Module

4.5. ZL Bracket

Specifically designed for inswinging doors, the ZL bracket ensures proper alignment and secure mounting of the magnetic lock and armature plate.

Magnetic lock mounted with ZL bracket for inswinging doors.

Figure 4.5: Magnetic Lock with ZL Bracket

5. Oppsett og installasjon

5.1. Koblingsskjema

Refer to the following diagram for correct wiring of all components to the power supply controller.

Detailed wiring diagram for the YUHANUS Access Control System, showing connections between power supply, magnetic lock, exit button, and remote control receiver.

Figur 5.1: Systemkoblingsskjema

5.2. Installasjonstrinn

  1. Mount the ZL Bracket: Securely attach the ZL bracket to the door frame and the door itself, ensuring proper alignment for the magnetic lock and armature plate.
  2. Install the Magnetic Lock: Mount the magnetic lock onto the ZL bracket on the door frame.
  3. Install the Armature Plate: Attach the armature plate to the door, aligning it precisely with the magnetic lock. Use the provided template for drilling holes if available.
  4. Mount the Exit Button: Install the stainless steel exit button at a convenient location inside the secured area.
  5. Mount the Power Supply Controller: Secure the power supply controller in a suitable, well-ventilated location.
  6. Wire the Components: Follow the wiring diagram (Figure 5.1) to connect the magnetic lock, exit button, and remote control receiver to the power supply controller. Pay close attention to polarity and terminal labels (N.O., N.C., GND, +12V, PUSH, CTRL+, CTRL-).
  7. Koble til strøm: Connect the power supply controller to a 110V-240V AC power source using the provided power plug connector.
  8. Test systemet: After all connections are made, apply power and test the functionality of the magnetic lock, exit button, and remote control.

6. Bruksanvisning

6.1. Unlocking with Remote Control

Press the unlock button on the remote control fob. The magnetic lock will disengage, allowing the door to be opened. The remote control has a maximum range of 165 feet.

6.2. Exiting with Push Button

From inside the secured area, press the stainless steel exit button. This will momentarily disengage the magnetic lock, allowing you to open the door.

6.3. Alarm Beeper Function

The magnetic lock features a built-in alarm beeper. If the door is not securely closed and the magnetic lock is not fully engaged after a set delay (configurable via the power supply controller), the alarm will sound to indicate an insecure state.

7. Vedlikehold

  • Rengjøring: Periodically clean the magnetic lock and armature plate surfaces to ensure optimal contact and holding force. Use a soft, dry cloth.
  • Tilkoblingssjekk: Kontroller regelmessig alle ledningsforbindelser for tetthet og tegn på slitasje eller korrosjon.
  • Funksjonalitetstest: Periodically test the magnetic lock, exit button, and remote control functionality to ensure they are operating correctly.

8. Feilsøking

ProblemMulig årsakLøsning
Magnetic lock does not engage.No power to the lock; incorrect wiring; armature plate misalignment; faulty lock.Check power supply and connections. Verify wiring against diagram. Adjust armature plate. Test lock with direct power.
Fjernkontrollen virker ikke.Remote battery dead; receiver not powered; receiver faulty; remote out of range.Replace remote battery. Check power to receiver. Ensure within 165ft range.
Exit button does not work.Incorrect wiring; faulty button.Verify wiring to the power supply. Test button continuity.
Alarm beeper sounds continuously.Door not fully closed; armature plate not making full contact; delay setting too short.Ensure door is fully closed. Check alignment of lock and plate. Adjust delay setting on power supply.

9. Spesifikasjoner

  • Merke: YUHANUS
  • Modellnummer: 767637528832
  • Låstype: Electromagnetic Lock (600lbs holding force)
  • Dørtype: Inswinging
  • Strømkilde: Hardwired Electrical Connection with Battery Backup (Battery not included)
  • Inngang Voltage: AC 110V-240V
  • Utgang Voltage: DC 12V (4A)
  • Tilkoblingsteknologi: Wired (for main components), Wireless (for remote control)
  • Kontrollmetode: Fjernkontroll, trykknapp
  • Maximum Remote Range: 165 fot
  • Varseltype: Entry (Alarm Beeper)
  • Varevekt: Omtrent 7.09 pund (3.22 kilogram)
  • Pakkedimensjoner: 11.85 x 9.76 x 3.27 tommer

10. Garanti og støtte

This product is covered by the standard manufacturer's warranty. For specific warranty details, please refer to the documentation provided with your purchase or contact YUHANUS customer support.

For technical assistance, troubleshooting, or replacement parts, please contact YUHANUS customer service through the retailer where the product was purchased or visit the official YUHANUS webnettsted for kontaktinformasjon for støtte.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.