Aramox TM619H-2

Aramox TM619H-2 Electronic Time Control Switch

Brukerhåndbok

1. Introduksjon

This manual provides detailed instructions for the installation, operation, and maintenance of your Aramox TM619H-2 Electronic Time Control Switch. Please read this manual thoroughly before using the device to ensure proper function and safety. Keep this manual for future reference.

2. Sikkerhetsinformasjon

  • Always disconnect power before installation or maintenance to prevent electric shock.
  • Installasjonen bør utføres av en kvalifisert elektriker eller en kyndig person.
  • Sørg for at ledningstilkoblingene er sikre og i samsvar med lokale elektriske forskrifter.
  • Ikke utsett enheten for overdreven fuktighet, støv eller ekstreme temperaturer.
  • The device is designed for indoor use unless otherwise specified.

3. Produktet er overview

The Aramox TM619H-2 is a digital time control switch designed for precise scheduling of electrical devices. It features an LCD digital display and supports both 24-hour and 12-hour time systems. This model operates on 12V DC and includes a memory backup function to retain programming during power interruptions (requires a 3V lithium battery, not included).

Nøkkelfunksjoner:

  • Digital LCD display for clear time and program viewing.
  • Supports 24-hour and 12-hour time systems.
  • Programmable ON/OFF events.
  • Memory backup during power outages (with installed battery).
  • Manuell overstyringsfunksjon.

Komponenter:

The device consists of a main body with an LCD display and control buttons on the front, and wiring terminals on the back.

Front view of the Aramox TM619H-2 Electronic Time Control Switch showing the LCD display and control buttons.

Figur 1: Foran view of the TM619H-2 timer switch, displaying the LCD screen and various control buttons such as CLOCK, TIMER, DAY, HOUR, MIN, and MANUAL.

4. Spesifikasjoner

TrekkSpesifikasjon
ProduktmodellTM619H-2
ProduktmaterialeABS
VisningstypeLCD digital skjerm
Arbeid VoltageDC12V
Hyppighet50/60 Hz
Nåværende vurdering30A
Battery (for memory)Lithium battery 3V (not included)
Produktdimensjoner3.15 x 3.15 x 1.97 tommer (8 x 8 x 5 cm)
Varevekt4.3 unser (122 gram)

5. Oppsett

5.1. Battery Installation (for Memory Backup)

The TM619H-2 requires a 3V lithium battery (e.g., CR2032, not included) for memory backup. This battery ensures that your programmed settings are retained during power outages. Locate the battery compartment, insert the battery with the correct polarity, and close the compartment.

5.2. Montering

The timer switch is designed for panel assembly. Secure the device in a suitable enclosure or panel cutout using appropriate mounting hardware (not included).

5.3. Kabling

Refer to the wiring diagram on the back of the device and the images below for correct connections. Ensure all connections are tight and insulated.

Tilbake view of the Aramox TM619H-2 Electronic Time Control Switch showing the wiring terminals labeled 1 to 5.

Figur 2: Bakside view of the TM619H-2 timer switch, illustrating the input and output terminals for wiring.

Comparison of new and old model wiring diagrams for the TM619H-2 timer switch.

Figure 3: Comparison of wiring configurations for new and old versions of the TM619H-2 model. Always refer to the diagram on your specific unit.

General Wiring Guide:

  • Input Power (DC12V): Connect your 12V DC power supply to the designated input terminals (typically labeled 'INPUT' or 'LINE').
  • Lastutgang: Connect the device you wish to control to the output terminals (typically labeled 'OUTPUT' or 'LOAD'). The timer acts as a switch for this load.
  • Ensure the load's current draw does not exceed the timer's maximum rating of 30A.

6. Bruksanvisning

6.1. Første oppstart og tilbakestilling

Upon first power-up or after battery installation, the display may show random characters. Press the R (Reset) button (usually a small recessed button requiring a pointed object) to clear all settings and initialize the timer.

6.2. Stille inn gjeldende tid

  1. Trykk på KLOKKE button and hold it.
  2. Mens du holder KLOKKE, trykk DAG for å angi gjeldende ukedag.
  3. Mens du holder KLOKKE, trykk TIME for å stille inn gjeldende time.
  4. Mens du holder KLOKKE, trykk MIN for å stille inn gjeldende minutt.
  5. Slipp ut KLOKKE knappen. Klokken er nå innstilt.

6.3. Switching 12/24-Hour System

To switch between 12-hour (AM/PM) and 24-hour formats, press the KLOKKE knappen og deretter TIMER knappen samtidig.

6.4. Programming ON/OFF Events

The TM619H-2 allows you to set multiple ON/OFF programs. Follow these steps:

  1. Trykk på TIMER knappen én gang. Displayet vil vise «1 PÅ».
  2. Pressen DAG to select the day(s) for this ON event (e.g., Mon-Fri, Sat-Sun, every day, specific day).
  3. Pressen TIME to set the desired hour for the ON event.
  4. Pressen MIN to set the desired minute for the ON event.
  5. Trykk på TIMER button again. The display will show "1 OFF".
  6. Repeat steps 2-4 to set the day(s), hour, and minute for the corresponding OFF event.
  7. Fortsett å trykke TIMER to cycle through other program settings (2 ON, 2 OFF, etc.).
  8. Etter at du har stilt inn alle ønskede programmer, trykker du på KLOKKE -knappen for å avslutte programmeringsmodus og gå tilbake til gjeldende tidsvisning.

6.5. Manuell overstyring

De HÅNDBOK button allows you to override the programmed settings temporarily. Pressing this button cycles through different modes:

  • PÅ: The output is continuously ON, ignoring programs.
  • AUTO PÅ: The output is currently ON and will follow the next programmed OFF event.
  • AUTO AV: The output is currently OFF and will follow the next programmed ON event.
  • AV: The output is continuously OFF, ignoring programs.

Select "AUTO ON" or "AUTO OFF" for the timer to resume automatic operation based on your programs.

7. Vedlikehold

  • Rengjøring: Tørk av enheten med en myk, tørr klut. Ikke bruk slipende rengjøringsmidler eller løsemidler.
  • Batteribytte: If the display becomes dim or programs are lost frequently during power interruptions, the 3V lithium backup battery may need replacement. Follow the battery installation steps in Section 5.1.
  • Undersøkelse: Sjekk ledningsforbindelsene med jevne mellomrom for tetthet og tegn på slitasje.

8. Feilsøking

ProblemMulig årsakLøsning
Skjermen er tom eller svak.No power supply; faulty wiring; dead backup battery.Check power connections. Ensure 12V DC supply. Replace backup battery.
Programmene kjører ikke.Timer is in manual ON/OFF mode; incorrect programming; current time not set.Set to AUTO ON/OFF mode using the MANUAL button. Verify program settings. Set current time correctly.
Programs are lost after power outage.Backupbatteriet er dødt eller ikke installert.Install or replace the 3V lithium backup battery.
Lasten slår seg ikke PÅ/AV.Incorrect wiring; faulty load; load exceeds current rating.Check load wiring. Test the load independently. Ensure load current is within 30A.

9. Garanti og støtte

For garantiinformasjon eller teknisk støtte, se dokumentasjonen som fulgte med ved kjøp, eller kontakt forhandleren din. Ta vare på kjøpskvitteringen som kjøpsbevis.