EARU EARU-1012

EARU elektrisk 3-fase automatisk overføringsbryter (ATS) - 440V 63A brukerhåndbok

Brand: EARU | Model: EARU-1012

1. Introduksjon

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your EARU Electric 3-Phase Auto Transfer Switch (ATS) - 440V 63A. Please read this manual thoroughly before installation and operation to ensure proper functionality and to prevent damage or injury.

The ATS is designed to provide uninterrupted power by automatically transferring loads between phases in a three-phase supply system. It features intelligent monitoring and protection against phase failure, over/under voltage, and overcurrent conditions, ensuring the stability and safety of connected equipment.

2. Sikkerhetsinformasjon

WARNING: Electrical shock hazard. Installation and servicing should only be performed by qualified personnel.

  • Always disconnect power before installing or servicing the ATS.
  • Sørg for at all kabling er i samsvar med lokale og nasjonale elektriske forskrifter.
  • Bekreft riktig voltage and current ratings before connecting the device.
  • Ikke bruk enheten hvis den ser ut til å være skadet.
  • Hold barn unna elektrisk utstyr.

3. Produktet er overview

The EARU Electric 3-Phase ATS is an intelligent device that continuously monitors your three-phase power supply. It automatically switches single-phase loads to a healthy phase in case of a phase failure or imbalance, ensuring continuous operation of critical equipment.

3.1. Pakkens innhold

  • 1 x EARU Electric 3-Phase Auto Transfer Switch (ATS)

3.2. Front Panel and Indicators

Front panel of EARU Electric 3-Phase ATS with digital display and control buttons

Bildebeskrivelse: The front panel of the ATS features a digital display showing voltage for L1, L2, L3 phases and current for L1. Below the display are indicators for Power, Over-voltage (>V), Under-voltage (<V), and Over-current (>I). Control buttons include 'SET' (Menu key), 'Digit+/Up', 'Digit-/Down', and 'Manual ON/OFF' (Power button).

The digital display provides real-time voltage readings for each phase (L1, L2, L3) and the current for L1. Status indicators alert you to the operational state and any detected faults:

  • Makt: Output indication.
  • >V: Over-voltage indikasjon.
  • <V: Under-voltage indikasjon.
  • >jeg: Over-current indication.

Control buttons allow for parameter settings and manual operation:

  • SETT: Menu key for accessing settings.
  • Digit+/Up: Increases value or navigates up in menus.
  • Digit-/Down: Decreases value or navigates down in menus.
  • Manuell PÅ/AV: Power button for manual control.

4. Oppsett og installasjon

The ATS is designed for standard DIN rail mounting. Ensure sufficient space for ventilation and wiring connections.

4.1. Koblingsskjema

Wiring diagram for EARU Electric 3-Phase ATS showing input and output connections

Bildebeskrivelse: A detailed wiring diagram illustrates the connection points for the ATS. The top terminals are labeled 'IN' with connections for N, L1, L2, L3. The bottom terminals are labeled 'OUT' with connections for N and L1. The diagram shows how to connect the three-phase input to the ATS and how a single-phase load (L1 and N) is connected to the output, with internal connections for phase monitoring and switching.

Follow the wiring diagram carefully. Incorrect wiring can lead to device malfunction or electrical hazards.

  • Connect the incoming three-phase power supply (N, L1, L2, L3) to the 'IN' terminals.
  • Connect the single-phase load (N, L1) to the 'OUT' terminals. The ATS will manage the phase transfer for the L1 output.
  • Ensure all connections are secure and tightened to prevent loose contacts and overheating.

4.2. Første oppstart

After completing the wiring, restore power to the system. The ATS will power on and begin monitoring the phases. The digital display will show the current voltage readings for each phase. If all phases are stable and within acceptable limits, the ATS will provide power to the output.

5. Bruksanvisning

The ATS operates automatically, but you can adjust its protection parameters to suit your specific requirements.

5.1. Forstå displayet og indikatorene

The digital display continuously shows the real-time voltage of each phase (L1, L2, L3) and the current on L1. The indicator lights provide quick visual feedback on the device's status and any detected anomalies.

Close-up of EARU Electric 3-Phase ATS digital display showing voltage and current readings

Bildebeskrivelse: Et nærbilde view of the ATS digital display. It shows '220V' for L1, L2, and L3, and '63.0A' for L1 current. Below these readings are small indicator icons for Power, >V (Over-voltage), <V (Under-voltage), and >I (Over-current).

5.2. Adjusting Protection Parameters

Use the 'SET' button to enter the parameter setting mode. Use the 'Digit+/Up' and 'Digit-/Down' buttons to navigate through settings and adjust values. Press 'SET' again to confirm and save changes.

Adjustable Protection Parameters
ParameterInnstillingsområdeStandardinnstilling
Innstillingsområde for overstrømsbeskyttelse1-63A/100A30A
Kontinuerlige overstrømsbeskyttelsestider0-20 gangerAV
Over Voltage Beskyttelsesinnstillingsområde230-300V270V
Over Voltage Innstillingsområde for gjenoppretting av beskyttelse225-295V265V
Under Voltage Beskyttelsesinnstillingsområde140-210V170V
Under Voltage Innstillingsområde for gjenoppretting av beskyttelse145-215V175V
Voltage & strømbeskyttelse Gjenopprettingsforsinkelse1-500-årene30 s

5.3. Automatic Phase Transfer

The ATS automatically monitors the three input phases (L1, L2, L3). If a phase failure or significant voltage imbalance (over/under voltage) is detected on the currently supplying phase, the device will automatically transfer the single-phase output load to a healthy, stable phase within the same supply. This process is designed to be seamless and rapid, minimizing power interruption to connected equipment.

5.4. Automatic Recovery

Once the primary phase recovers and stabilizes, the ATS will intelligently switch the load back to the primary source, ensuring optimal power distribution and preventing equipment damage from unstable power. The recovery delay can be configured as per your operational needs.

6. Vedlikehold

The EARU Electric ATS is designed for minimal maintenance. However, periodic checks are recommended to ensure optimal performance and longevity.

  • Rengjøring: Hold enheten ren og fri for støv og rusk. Bruk en tørr, myk klut til rengjøring. Ikke bruk flytende rengjøringsmidler.
  • Tilkoblingskontroller: Kontroller alle ledningsforbindelser med jevne mellomrom for å sikre at de forblir stramme og fri for korrosjon.
  • Miljøforhold: Sørg for at driftsmiljøet holder seg innenfor de angitte temperatur- og fuktighetsområdene.

7. Feilsøking

If you encounter issues with your ATS, refer to the following common problems and solutions:

Feilsøkingsveiledning
ProblemMulig årsakLøsning
Ingen strømutgangNo input power; all phases unstable; device in fault state.Check incoming power supply. Verify all phases are stable. Check fault indicators.
">V" or "<V" indicator litOver-voltage eller under-voltage detected on a phase.Sjekk inngangsvoltage stability. The ATS will automatically transfer if another phase is healthy.
">I" indicator litOver-current detected on the output.Reduce load on the output. Check for short circuits in the connected equipment.
Device not transferring phasesNo healthy alternative phase available; transfer delay setting too long.Ensure at least one healthy phase is present. Check and adjust the transfer delay settings.
Digital skjerm fungerer ikkeNo power to the device; internal fault.Check power supply. If power is present and display is off, contact support.

For issues not covered here, please contact EARU customer support.

8. Spesifikasjoner

Detailed specifications and dimensions of EARU Electric 3-Phase ATS

Bildebeskrivelse: This image displays the physical dimensions of the ATS (90mm width, 96mm height, 66mm depth) and a table of detailed technical specifications, including current rating, voltage, frequency, and various protection setting ranges.

TrekkDetalj
MerkeEARU
ModellnummerEARU-1012
DriftsmodusPÅ AV
Nåværende vurdering63 Amps
Driftsvoltage440 Volts (AC 3*220V (N-L1/L2/L3))
Nominell frekvens50/60 Hz
KontakttypeNormalt åpen
KoblingstypeStandard DIN rail 63A
Krets type4-veis
KontaktmaterialeKopper
Innstillingsområde for overstrømsbeskyttelse1-63A/100A (Default 30A)
Kontinuerlige overstrømsbeskyttelsestider0–20 ganger (standard AV)
Over Voltage Beskyttelsesinnstillingsområde230–300 V (standard 270 V)
Over Voltage Innstillingsområde for gjenoppretting av beskyttelse225–295 V (standard 265 V)
Under Voltage Beskyttelsesinnstillingsområde140–210 V (standard 170 V)
Under Voltage Innstillingsområde for gjenoppretting av beskyttelse145–215 V (standard 175 V)
Voltage & strømbeskyttelse Gjenopprettingsforsinkelse1–500 sekunder (standard 30 sekunder)
Varevekt450 g
Pakkedimensjoner15 x 15 x 15 cm
OpprinnelseslandIndia

9. Garanti og støtte

9.1. Garantiinformasjon

The EARU Electric 3-Phase Auto Transfer Switch (ATS) comes with a 1 års produsentgaranti fra kjøpsdatoen. Denne garantien dekker material- og produksjonsfeil ved normal bruk. Den dekker ikke skader forårsaket av feil installasjon, misbruk, ulykker eller uautoriserte modifikasjoner.

9.2. Kundestøtte

For technical assistance, warranty claims, or any questions regarding your EARU Electric ATS, please contact your retailer or the manufacturer directly. Ensure you have your product model number (EARU-1012) and proof of purchase available when contacting support.