1. Introduksjon
This user manual provides detailed instructions for the safe and effective operation of your Hcalory TS-M Thermal Imaging Camera with Multimeter. This device integrates thermal imaging capabilities with a professional-grade digital multimeter, offering a versatile tool for diagnostics and measurement in various applications. Please read this manual thoroughly before using the device and retain it for future reference.
2. Sikkerhetsinformasjon
Always observe the following safety precautions to prevent injury and avoid damage to the instrument or the equipment under test.
- Ikke bruk enheten hvis den ser skadet ut, eller hvis isolasjonen på testledningene er svekket.
- Ensure the correct function and range are selected before making any measurements.
- Ikke overskrid de maksimale inngangsgrensene for noen funksjon.
- Utvis ekstrem forsiktighet når du arbeider med voltagover 30 V AC RMS, 42 V peak eller 60 V DC. Disse volumenetagdet utgjør en sjokkfare.
- Koble fra strømmen til kretsen og utlad all høyvolumsladning.tage-kondensatorer før du utfører motstands-, kontinuitets- eller diodetester.
- Use only the test leads provided or approved by Hcalory.
- Hold fingrene bak fingerbeskytterne på testprobene under bruk.
- Ikke bruk enheten i eksplosive miljøer med gass, damp eller støv.
- Refer to the specifications section for detailed electrical ratings and environmental conditions.
3. Pakkens innhold
Verify that all items listed below are present and undamaged upon opening the package. If any item is missing or damaged, contact your retailer.

Figur 3.1: Pakkeinnhold
The image displays the complete contents of the Hcalory TS-M package. These include (1) an EV Toolkit (carrying case), (2) the Instruction Manual, (3) a USB Charging Cable/Probe, (4) the Thermal Imaging Multimeter 2-in-1 device, (5) Multimeter Probes, and (6) a Macro Magnetic Lens.
- Thermal Imaging Multimeter (Model TS-M)
- Multimeter Test Leads (Probes)
- USB ladekabel
- Macro Magnetic Lens
- Bruksanvisning
- Carrying Case (EV Toolkit)
4. Produktet er overview
The Hcalory TS-M combines a high-resolution thermal imager with a full-function digital multimeter, designed for efficiency and accuracy in various diagnostic tasks. Its robust construction ensures durability in demanding environments.

Figure 4.1: Device Front and Back View
This image shows the Hcalory TS-M device from both the front and back. The front features the display screen, control buttons, and multimeter input jacks. The back includes the IR camera lens and a macro lens attachment point.
Nøkkelfunksjoner:
- Integrated Thermal Imaging: High-resolution thermal sensor for visualizing temperature differences.
- Professional Multimeter: Full range of electrical measurement functions including voltage, strøm, motstand, kontinuitet og diodetesting.
- TISR Resolution: Enhanced thermal imaging resolution of 240x240 pixels for clearer thermal details.
- Macro Lens Capability: Magnetic macro lens for detailed thermal inspection of small components.
- Robust design: Built to withstand drops, dust, and water splashes, suitable for tough job sites.
- Lang batterilevetid: 1500 mAh battery providing up to 7 hours of continuous operation.
5. Oppsett
5.1 Lading av enheten
Before first use, fully charge the Hcalory TS-M. Connect the provided USB charging cable to the device's USB-C port and to a standard USB power adapter (not included) or a computer USB port. The charging indicator on the device will show charging status.

Figur 5.1: Lade enheten
The image illustrates the Hcalory TS-M connected via its USB-C port for charging. The display indicates a full battery and an estimated operational time of 7 hours, powered by its 1500 mAh battery.
5.2 Feste testledninger
For multimeter functions, insert the red test lead into the VΩ(+) jack and the black test lead into the COM(-) jack. Ensure a secure connection.
5.3 Attaching Macro Lens (Optional)
For detailed thermal inspection of small components, attach the magnetic macro lens to the designated area on the back of the device, over the IR camera lens. The magnetic attachment ensures easy installation and removal.

Figure 5.2: Macro Lens Attachment
This image demonstrates the Hcalory TS-M with its magnetic macro lens attached to the rear. The display shows a comparison of thermal images, highlighting the enhanced detail provided by the 5x magnification of the macro lens compared to 1x without it, useful for pinpoint accuracy on small components.
6. Bruksanvisning
6.1 Strøm på/av
Press and hold the power button (usually marked with a circle and a vertical line) to turn the device on or off.
6.2 Thermal Imaging Mode
Upon powering on, the device typically defaults to thermal imaging mode. The screen will display a thermal image of the environment. Use the navigation buttons (up, down, left, right, OK) to access menus and adjust settings such as color palettes, emissivity, and temperature units.

Figur 6.1: Termografi i bruk
The image shows a user holding the Hcalory TS-M, with its screen displaying a thermal image of an engine. This illustrates the device's capability to provide immediate visual temperature data, aiding in quick problem diagnosis.
6.2.1 TISR Resolution Enhancement
The Hcalory TS-M features TISR (Thermal Imaging Super Resolution) technology, enhancing the thermal image resolution to 240x240 pixels for greater clarity. This feature can typically be toggled on or off via the device's menu settings to suit different inspection needs.

Figure 6.2: TISR Resolution Comparison
This image demonstrates the impact of TISR technology. On the left, a thermal image with TISR enabled shows a resolution of 240x240, providing significantly more detail. On the right, the same scene with TISR off displays a lower resolution of 64x64, highlighting the clarity improvement offered by the enhanced resolution feature.
6.3 Multimetermodus
To switch to multimeter mode, use the mode selection button or navigate through the menu. Once in multimeter mode, select the desired measurement function (e.g., AC Voltage, DC voltage, Resistance, Continuity, Diode Test) using the function dial or buttons. Connect the test leads to the circuit under test as appropriate for the selected function.

Figure 6.3: Multimeter Functionality
The image shows the Hcalory TS-M in use as a multimeter, with its probes connected to a circuit board. The screen displays electrical measurement readings, demonstrating its capability for precise electrical diagnostics.
6.3.1 Common Multimeter Functions:
- Voltage-måling (AC/DC): Connect probes in parallel with the component or circuit to measure voltage.
- Motstandsmåling: Ensure the circuit is de-energized. Connect probes across the component to measure resistance.
- Kontinuitetstest: For checking if a circuit is complete. The device will typically emit an audible tone if continuity is detected.
- Diodetest: For checking the functionality of diodes.
7. Vedlikehold
7.1 Rengjøring
Tørk av enheten casing med annonseamp cloth and mild detergent. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from any power source before cleaning. Do not immerse the device in water.
7.2 Batteristell
The device contains a rechargeable lithium-ion battery. For optimal battery life, avoid fully discharging the battery frequently. If storing the device for an extended period, charge it to approximately 50% every few months.
7.3 Fuse Replacement (Multimeter)
The multimeter functions are protected by internal fuses. If a current measurement function fails, the fuse may need replacement. Refer to the specifications for the correct fuse type and rating. Fuse replacement should only be performed by qualified personnel.
8. Feilsøking
| Problem | Mulig årsak | Løsning |
|---|---|---|
| Enheten slås ikke på. | Lavt eller utladet batteri. | Lad enheten med den medfølgende USB-kabelen. |
| Thermal image is blurry or unclear. | Lens is dirty; TISR is off. | Clean the IR lens with a soft cloth. Enable TISR in settings. |
| Multimeter readings are incorrect or zero. | Incorrect function selected; test leads not properly connected; blown fuse. | Verify function selection. Ensure leads are securely connected. Check and replace fuse if necessary (qualified personnel only). |
| Enheten fryser eller slutter å reagere. | Programvarefeil. | Perform a soft reset by holding the power button for 10-15 seconds. If persistent, a factory reset may be required (refer to advanced settings). |
9. Spesifikasjoner
| Trekk | Spesifikasjon |
|---|---|
| Modell | TS-M |
| Merke | HCALORY |
| Termisk oppløsning | 240x240 pixels (with TISR) |
| Temperaturområde | -68°F to 1022°F (approximately -55°C to 550°C) |
| Batteritype | 12V Lithium-ion (included) |
| Batterikapasitet | 1500 mAh (5.55 wattimer) |
| Driftstid | Opptil 7 timer |
| Varevekt | 599 g |
| Pakkedimensjoner | 24.41 x 15.09 x 6.71 cm |
| Multimeter funksjoner | Voltage (AC/DC), Current, Resistance, Continuity, Diode Test |
| Inkluderte komponenter | Thermal Imaging Camera with Multimeter, Test Leads, USB Cable, Macro Lens, Carrying Case, Manual |
| Opprinnelsesland | Kina |
10. Garanti og støtte
For warranty information and technical support, please refer to the warranty card included with your product or visit the official Hcalory webnettstedet. Ta vare på kjøpskvitteringen som kjøpsbevis for garantikrav.
In case of issues not covered in the troubleshooting section, or for service inquiries, please contact Hcalory customer support.